PCME STACK 181

The PCME STACK 181 is suitable for measuring particle emissions after both bag filter and electrostatic precipitator arrestment plant.

Utilizing the patented ProScatter™ Forward Scatter measurement technique for measuring particulate concentration levels, typically between 0.06 mg/m3 to 300 mg/m3, this measurement technique offers improved levels of performance which make the PCME STACK 181 very suitable for use as a PM CPMS or PM CEMS that need to comply with US EPA PS-11 for Site Operators looking to satisfy the recent MACT and MATS rules.

Due to the inherent rugged design, the PCME STACK 181 Particulate Monitoring System is suitable for use in a wide range of applications within the Power, Incineration, Cement, Chemical, Metal, Mineral and Petrochemical industries:

  • Reliable and rugged design, proven for long term operation at elevated temperatures and with minimized instrument maintenance
  • Forward Scatter measurement technique with automatic zero and upscale checks that fully challenge the system's ability to measure forward scattered light and satisfy daily drift checks

The PCME STACK 181 is suitable for measuring particle emissions after both bag filter and electrostatic precipitator arrestment plant.

180-PCME-Stack-990


The PCME STACK 181 is suitable for:

– After bag filter, cyclone and electrostatic precipitator arrestment plant
– Non-condensing / dry flue gases*
– Both constant and variable flue gas velocities
– Corrosive flue gases (corrosion protection option)
– Variable particulate size
– Explosive atmosphere zones 2 and 21
* For wet / condensing flue gas applications see PCME STACK 181 WS

 

Feature and benefits

  • Robust design with no critical moving parts
  • Available for use in high-temperature stack conditions and Ex hazardous zones
  • Easy to fit multi-patterned flange
  • Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
  • For use as PM-CPMS or PM-CEMS that need to comply with PS-11
  • ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
  • Features automatic zero and upscale checks that fully challenge the system’s ability to measure forward-scattered light and satisfy daily drift checks
  • Easily audited with manual filters

 

Main application

  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration.
  • Non-condensing / dry flue gases
  • Typical Applications
  • Incineration
  • Metals eg Steel/Aluminum
  • Minerals eg Cement/Gypsum
  • Chemicals eg TiO2 / Refinery
  • Power Generation Plant eg Coal/Biomass